The Pro-Series™ II large-capacity drying
tumblers are designed with quality internal components, easy-to-use
programmable microprocessor controls and a multitude of features that
dramatically increase laundry production and energy-efficiency. Properly
balanced airflow, heat input and basket volume allows maximum production
when matched with Continental Pro-Series Washer-Extractors.
Durability Unmatched
Durability characterizes Pro-Series II. The tumblers feature rugged
cylinders; dual motors with overload protection; steel front, side and top
panels coated inside and out with electrostatically applied,
backed-on paint for superior bonding and corrosion resistance; an all-belt
drive system with cast-iron pulleys and permanently sealed bearings for
quiet, low-maintenance operation; and durable kick-plates and cart bumpers
to protect tumblers from nicks and scrapes. An exclusive annealed stainless
steel backplate (available only on CG50-60 and CG75-85 models) contributes
to longer machine life and also reduces friction against tumbling laundry—extending
linen life. No wonder Pro-Series II Tumblers are backed by an
industry-leading factory warranty!
Ergonomic & Easy to Maintain
Ergonomic and easy to maintain, Pro-Series II dryers feature
self-cleaning lint screens that support maximum airflow. Further
contributing to ease of maintenance are conveniently accessible components
and an automatic backdraft damper to prevent outside air from entering the
laundry room. Because ergonomics matter, the tumblers feature oversized
steel doors with reinforced metal door bars and hinges—simplifying loading
and unloading and protecting the tumbler from outside impacts!
Radial Airflow & Quick-Drying Convenience
Pro-Series II large-capacity drying tumblers are designed with radial
airflow—a system that captures heated air intake and distributes it evenly
throughout the cylinder. Radial airflow ensures maximum load separation for
big loads and bulky items and utilizes the tumbler's complete capacity for
quick, even drying. As heated air is released from the top of the basket,
linens, which are rotated from the bottom to the top, fall and separate
throughout the entire cylinder (see fig. 1). Simultaneously, heated air is
pushed through and around the load—eliminating hot spots and expediting the
drying process.
Energy-Efficiency
Several key features contribute to heightened energy-efficiency on
Pro-Series II tumblers, including instant electronic ignition, which reduces
drying time and conserves energy; a modular electrical system for added
reliability and easy servicing; and a multiple burner heat system to
efficiently and quickly reach desired temperatures. Pro-Series II delivers
quick drying thanks to carefully balanced heat energy input and airflow.
Perfectly balanced airflow prevents extra wear on fabrics and cuts drying
time. The fully enclosed heat system captures intake air and preheats it
before entering the tumbler—reducing energy costs without increasing drying
time.
ISS Fire Sensing and Extinguishing
Continental understands the importance of safety to your on-premise
laundry. That's why we've equipped Pro-Series II large-capacity dryers with
an optional extinguishing device designed to squelch dryer fires before they
get out of hand.
Pro-Series Microprocessor Control
Pro-Series II Dryers feature a highly advanced control to make laundries
more productive. Equipped with a multitude of features, the control offers
four time-dry or auto-dry cycles and a no-heat cycle—making for simple
operation. An auto-dry feature reduces over drying and the resulting risk of
fire by automatically cooling the load once the predetermined dryness level
is reached. An anti-wrinkle feature reduces the occurrence of wrinkles by
initiating an unheated airflow and tumble action after the end-of-cycle
signal.
 |
 |
 |
| Efficient Dual
motors provide separate power for the basket and fan—maximizing
efficiency |
Ergonomic A
self-cleaning lint screen deposits lint into a vast storage chamber
for fast removal. |
Easy-to-Use The
highly advanced control simplifies the process of doing laundry. |

| |
CG50-60 |
CG75-85 |
CG115-25 |
CG165-75 |
| Capacity lbs (kg) |
up to 60 (24) |
up to 85 (34) |
up to 125 (50) |
up to 175 (70) |
| Basket Diameter inch (mm) |
37 (939) |
37 (939) |
44 (1118) |
50.75 (1289) |
| Basket Volume cu. ft. (m²) |
30 (762) |
36 (914) |
41 (1041) |
42.5 (1080) |
|
Crated Weight lbs (kg) |
Gas/Electric |
| |
Steam |
|
|
|
|
|
|
Net Weight lbs (kg) |
Gas/Electric |
| |
Steam |
|
|
|
|
|
|
Height inch (mm) |
Gas/Electric |
| |
Steam |
|
|
|
|
|
| Depth inch (mm) |
47 (1194) |
53 (1346) |
67.92 (1725) |
68.85 (1749) |
| Width inch (mm) |
38.62 (981) |
38.62 (981) |
46.38 (1178) |
53.12 (1349) |
| Shipping Dimensions inch (mm) |
41.5 x 52.1 x 81
(1054 x 1323 x 2057) |
41.5 x 56.4 x 81
(1054 x 1433 x 2057) |
48.5 x 72 x 90
(1232 x 1829 x 2286) |
58 x 74.5 x 99
(1473 x 1892 x 2515) |
| Door Opening inch (mm) |
26.89 (683) |
26.89 (683) |
26.89 (683) |
26.89 (683) |
| Floor to Door inch (mm) |
28.75 (730) |
28.75 (730) |
31.38 (797) |
33.86 (860) |
| Exhaust Diameter inch (mm) |
8 (203) |
8 (203) |
10 (254) |
12 (305) |
|
Exhaust Air Flow cfm (l/s) |
60 Hz |
| |
50 Hz |
|
|
|
|
|
| Motor Power Hp (kW) |
2-½ (0.37) |
2-¾ (0.56) |
— |
— |
|
Reversing Motor Power Hp (kW) |
Basket |
| |
Fan |
|
|
|
|
|
| Electric Heating kW |
30 |
30 |
— |
— |
| Gas Inlet Diameter inch |
½ N.P.T. |
½ N.P.T. |
¾ N.P.T. |
1 N.P.T. |
| Gas Heating BTU/h (Kcal/h) |
120,000 (30240) |
165,000 (41580) |
300,000 (75570) |
395,000 (99500) |
| Steam Inlet Diameter inch |
¾ N.P.T. |
¾ N.P.T. |
¾ N.P.T. |
¾ N.P.T. |
| Condensate Outlet Diameter inch |
¾ N.P.T. |
¾ N.P.T. |
¾ N.P.T. |
1 N.P.T. |
|
Steam Heating BTU/h (kW) |
at 100 PSI (6.9 bar) |
| |
at 15 PSI (1.0 bar) |
|
| 178,000 (52) |
| 119,000 (34.8) |
|
| 210,000 (61.6) |
| 141,000 (41.2) |
|
| 405,000 (118.5) |
| 272,000 (79.7) |
|
| 648,000 (189.7) |
| 433,000 (126.9) |
|
|
BHP Consumption BHP |
at 100 PSI (6.9 bar) |
| |
at 15 PSI (1.0 bar) |
|
|
|
|
|
|
Available Voltages/Amp (Rev Amps) |
| Gas/Steam |
120/60/1 |
| |
200-208/240/60/1 |
| |
200-208/240/60/3 |
| |
380/60/3 |
| |
440/60/3 (Steam) |
| |
460-480/60/3 |
| |
230-240/50/1 |
| |
200/50/3 |
| |
230-240/50/3 |
| |
380/400-415/50/3 |
|
| |
| 9.3 |
| 5.1/5.1 |
| 2.8/2.8 (4.0/4.0) |
| 1.6/2.0 |
| 1.4 (1.9) |
| 1.4 (1.9) |
| 6.3 (6.9) |
| 3.3 (4.2) |
| 3.1 (4.3) |
| 1.6/1.6 (2.0/2.0) |
|
| |
| 13.8 |
| 7.6/7.6 |
| 3.8/3.8 (4.3/4.3) |
| 1.8/2.1 |
| 1.9 (2.1) |
| 1.9 (2.1) |
| 6.7 (7.0) |
| 3.5 (4.5) |
| 3.5 (4.9) |
| 1.8/1.8 (2.1/2.1) |
|
|
|
| Electric |
200-208/60/3 |
| |
240/60/3 |
| |
380/60/3 |
| |
440/60/3 |
| |
480/60/3 |
| |
240/50/1 (21kW heater) |
| |
200/50/3 |
| |
230/50/3 |
| |
240/50/3 |
| |
380/50/3 |
| |
400-415/50/3 |
|
| 89 (88) |
| 79 (78) |
| 47 (48) |
| 41 (41) |
| 38 (38) |
| 93/95 |
| 84 (85) |
| 73 (75) |
| 79 (78) |
| 47 (48) |
| 43 (44) |
|
| 89 (88) |
| 79 (78) |
| 47 (48) |
| 41 (41) |
| 38 (38) |
| — |
| 84 (85) |
| 73 (75) |
| 79 (78) |
| 47 (48) |
| 43 (44) |
|
|
|